Solution

Continuous Emission Monitoring Systems (CEMS)

Complete continuous emission monitoring systems for DOE reporting: gas, dust and opacity analyzers, sampling systems and data links, supplied, installed and maintained by LKS.

Technician inspecting an emission analyzer probe on an industrial stack

Overview

From instrument supply to a working system.

A continuous emission monitoring system (CEMS) measures the pollutants leaving a stack around the clock and provides the data that plant operators need for regulatory reporting. In Malaysia, CEMS is required under the Environmental Quality (Clean Air) Regulations 2014 for the source activities listed in the Department of Environment’s CEMS guidelines, including heat and power generation above 10 MWe, cement and other non-metallic industries, oil and gas facilities, ferrous and non-ferrous metal production, waste incineration, and fuel burning equipment above the prescribed dust load.

Compliance is assessed on the recorded data. Over each calendar year, no daily average may exceed the emission limit value and no half-hourly average may exceed twice that value. Opacity is averaged over one minute and other parameters over 30 minutes, so the reliability of the analyzers and of the data chain matters as much as the instruments themselves.

A complete system brings together the stack instruments, namely extractive gas analyzers with heated sampling probes and sample gas coolers, in-situ gas analyzers, and dust and opacity monitors, with a data acquisition system (DAS) that records the readings and a data interface system (DIS) that transmits them to the DOE system for CEMS.

LKS has supplied industrial instrumentation since 1998, and CEMS is one of the systems we manufacture in Malaysia. Our engineers design, supply, install and commission each system for its source, and support it throughout its working life with calibration, quality assurance testing support, maintenance and spare parts on request.

Guides

Learn more about this solution.

  1. CEMS for Power Plants01

    CEMS for Power Plants

    Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
  2. CEMS for Cement Plants02

    CEMS for Cement Plants

    Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
  3. CEMS for Oil and Gas Facilities03

    CEMS for Oil and Gas: Refineries and Natural Gas Facilities

    Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
  4. Palm Oil04

    CEMS for Palm Oil Mills

    Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
  5. CEMS for Waste Incinerators05

    CEMS for Waste Incinerators

    Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
  6. CEMS for Iron and Steel Mills06

    CEMS for Iron and Steel Mills (Ferrous Metals)

    Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
  7. CEMS for Non-Ferrous Metal Plants07

    CEMS for Non-Ferrous Metal Plants

    Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more
  8. CEMS for Glass, Ceramic and Lime Plants08

    CEMS for Glass, Ceramic and Lime Plants

    Continuous emission monitoring system (CEMS) for glass furnaces, ceramic kilns and quicklime or dolomite rotary furnaces, using extractive and in-situ gas analysers and a particulate analyser to measure SO2, NO2 and total PM.Read more
  9. CEMS for Sugar Mills09

    CEMS for Sugar Mills

    Continuous emission monitoring system (CEMS) for sugar mills, combining extractive and in-situ analysers with a particulate in-situ analyser to measure total PM/dust and opacity against the DOE limits of 150 mg/m³ at 12% CO₂ and 20% opacity.Read more
  10. CEMS for Rice Mills10

    CEMS for Rice Mills

    Continuous emission monitoring system (CEMS) for rice mills that measures total particulate matter (PM/dust) and opacity at the stack, using extractive or in-situ dust and opacity analysers with DAS and DIS reporting to DOE.Read more
  11. CEMS for Saw Mills11

    CEMS for Saw Mills

    Continuous emission monitoring system (CEMS) for saw mill stacks that measures total particulate matter and opacity with extractive or in-situ dust and opacity analysers, sending data to the DOE server.Read more
  12. Technician inspecting an emission analyzer probe on an industrial stack12

    CEMS Calibration, Quality Assurance and Maintenance

    How a CEMS stays accurate and compliant after commissioning: the functional test, QAL2 calibration, QAL3 drift checks and the annual surveillance test, with maintenance, spare parts and on-site support from LKS.Read more
  13. CEMS remote monitoring system layout13

    CEMS Data Acquisition and DOE Reporting (DAS and DIS)

    How CEMS readings travel from the stack to the Department of Environment: the data acquisition system (DAS) that records them and the data interface system (DIS) that transmits them to the DOE system for CEMS.Read more
  14. UV-DOAS gas analyzer, MGL series14

    CEMS for Chemical and Petrochemical Plants

    Continuous emission monitoring for thermal oxidizers at chemical and petrochemical plants: NO2, NH3, SO2, particulate matter and opacity, measured with UV-DOAS, NDIR and dust and opacity analyzers.Read more

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.