Continuous Emission Monitoring Systems (CEMS)
CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.

This continuous emission monitoring system (CEMS) for palm oil mills measures stack emissions so that mills can report against the emission limits for their sector. Mill boilers are regulated as fuel burning equipment under the Environmental Quality (Clean Air) Regulations 2014, and the Department of Environment’s CEMS guidelines set an opacity limit of 20% and a total particulate matter limit of 150 mg/m³ at 12% CO₂ for solid fuel where the dust load emitted is 2.5 kg/h or more. The system can combine extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers on the stack, with signals carried on 4–20 mA lines to a data acquisition PC and transmitted over TCP/IP to the DOE server.
Features
- Measures total PM/dust and opacity at the stack
- Choice of extractive or in-situ sampling for dust and opacity
- Extractive principles: light scatter and beta absorption
- In-situ principles: transmissometry, triboelectric, double pass and single pass
- Data Acquisition System (DAS) and Data Interface System (DIS) for reporting
Emission limit values
- Opacity: 20%, for any fuel where the total dust emission is 2.5 kg/h or more, or where the smoke is darker than Shade No. 2 on the Ringelmann chart
- Total particulate matter: 150 mg/m³ at 12% CO₂, for solid fuel where the dust load emitted is 2.5 kg/h or more
Because biomass fuel varies from batch to batch, DOE notes that plants burning it may need a QAL2 calibration every year in place of the annual surveillance test.
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data Acquisition System (DAS)
- Data Interface System (DIS)
Applications
- Palm oil mill stacks
- Emission compliance reporting to DOE
LKS supplies CEMS for palm oil mills in Malaysia, with installation, calibration and after-sales support. Contact our engineers for a system design and quotation.
Specifications
| Item | Details |
|---|---|
| Analyzer types | Extractive gas analyzers, in-situ gas analyzers, particulate in-situ analyzers |
| Measured parameters | Total PM / dust, opacity |
| Total PM / dust: extractive principles | Light scatter, beta absorption |
| Total PM / dust: in-situ principles | Transmissometry / triboelectric, double pass, single pass |
| Opacity: extractive principles | Light scatter, beta absorption |
| Opacity: in-situ principles | Transmissometry / triboelectric, double pass, single pass |
| Emission limits (DOE) | Opacity 20%; total PM 150 mg/m³ at 12% CO₂ (solid fuel, dust load ≥ 2.5 kg/h) |
| Data systems | Data Acquisition System (DAS), Data Interface System (DIS) |
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
05CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
06CEMS for Non-Ferrous Metal Plants
Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.