Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.

A continuous emission monitoring system (CEMS) for waste incinerators measures the pollutants that incinerators of all sizes must report under DOE requirements. The system combines extractive gas analysers, in-situ gas analysers and an in-situ particulate analyser, with a data acquisition system (DAS) and data interface system (DIS) to record and transfer the results. Each pollutant can be measured with several analyser principles, extractive or in-situ, so the configuration can be chosen to suit the stack and the parameters required.
Features
- Extractive gas analysers, in-situ gas analysers and in-situ particulate analysers
- Measures total PM, NMVOC as total C, HCl, HF, SO2, NO2 and CO
- Data acquisition system (DAS) and data interface system (DIS)
- Choice of extractive or in-situ sampling for each gas
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data acquisition system (DAS)
- Data interface system (DIS)
Emission limits for waste incinerators (all sizes)
- Total PM: 100 mg/m³
- NMVOC as total C: 10 mg/m³
- Hydrogen chloride (HCl): 40 mg/m³
- Hydrogen fluoride (HF): 1 mg/m³
- SO2: 50 mg/m³
- NO2: 200 mg/m³
- CO: 50 mg/m³
Limits are referenced to 11% O₂. DOE applies the same limits to fuel burning equipment that uses waste, scheduled waste or by-products as fuel.
Measuring principles
- SO2: extractive NDIR, NDUV, GFC, FTIR, PAS or fluorescence; in-situ DOAS, GFC or FTIR
- NO2: extractive NDUV, PAS or fluorescence; in-situ DOAS
- CO: extractive NDIR, GFC, FTIR or PAS; in-situ DOAS, GFC, FTIR or TLD
- NMVOC: extractive PAS; in-situ DOAS
- HCl and HF: extractive FTIR or PAS; in-situ DOAS, FTIR or TLD
- Total PM / dust: extractive light scatter or beta absorption; in-situ transmissometry, triboelectric, double pass or single pass
Applications
- Waste incinerators of all sizes requiring CEMS
LKS supplies CEMS for waste incinerators in Malaysia, with installation, calibration and after-sales support. Contact our engineers for system configuration and a quotation.
Products
Equipment for this application.

Multigas Analyzer
Multigas analyzers for flue gas and process gas, measuring SO2, NOx, CO, CO2, O2, NH3 and more by UV DOAS, NDIR, TDLAS or electrochemical principles, with Modbus outputs.View range
Single Parameter Gas Analyzer
Single parameter gas analyzers for emission and process monitoring: mercury by CV-AFS, VOC by FID or PID, and a flameproof laser extractive analyzer for difficult sample conditions.View range
Dust & Opacity Analyzers
Dust and opacity analyzers for continuous particulate monitoring in stacks and ducts, using transmittance, scattered light, backscatter, extractive and triboelectric principles.View range
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
05CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
06CEMS for Non-Ferrous Metal Plants
Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.