Continuous Emission Monitoring Systems (CEMS)

CEMS for Waste Incinerators

Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.

CEMS for Waste Incinerators

A continuous emission monitoring system (CEMS) for waste incinerators measures the pollutants that incinerators of all sizes must report under DOE requirements. The system combines extractive gas analysers, in-situ gas analysers and an in-situ particulate analyser, with a data acquisition system (DAS) and data interface system (DIS) to record and transfer the results. Each pollutant can be measured with several analyser principles, extractive or in-situ, so the configuration can be chosen to suit the stack and the parameters required.

Features

  • Extractive gas analysers, in-situ gas analysers and in-situ particulate analysers
  • Measures total PM, NMVOC as total C, HCl, HF, SO2, NO2 and CO
  • Data acquisition system (DAS) and data interface system (DIS)
  • Choice of extractive or in-situ sampling for each gas

DOE requirements

  • Supplier listed as an appointed and approved company on the DOE website
  • Data acquisition system (DAS)
  • Data interface system (DIS)

Emission limits for waste incinerators (all sizes)

  • Total PM: 100 mg/m³
  • NMVOC as total C: 10 mg/m³
  • Hydrogen chloride (HCl): 40 mg/m³
  • Hydrogen fluoride (HF): 1 mg/m³
  • SO2: 50 mg/m³
  • NO2: 200 mg/m³
  • CO: 50 mg/m³

Limits are referenced to 11% O₂. DOE applies the same limits to fuel burning equipment that uses waste, scheduled waste or by-products as fuel.

Measuring principles

  • SO2: extractive NDIR, NDUV, GFC, FTIR, PAS or fluorescence; in-situ DOAS, GFC or FTIR
  • NO2: extractive NDUV, PAS or fluorescence; in-situ DOAS
  • CO: extractive NDIR, GFC, FTIR or PAS; in-situ DOAS, GFC, FTIR or TLD
  • NMVOC: extractive PAS; in-situ DOAS
  • HCl and HF: extractive FTIR or PAS; in-situ DOAS, FTIR or TLD
  • Total PM / dust: extractive light scatter or beta absorption; in-situ transmissometry, triboelectric, double pass or single pass

Applications

  • Waste incinerators of all sizes requiring CEMS

LKS supplies CEMS for waste incinerators in Malaysia, with installation, calibration and after-sales support. Contact our engineers for system configuration and a quotation.

Download the CEMS for Waste Incinerators catalogue (PDF)

Read next

Related topics.

  1. CEMS for Power Plants01

    CEMS for Power Plants

    Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
  2. CEMS for Cement Plants02

    CEMS for Cement Plants

    Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
  3. CEMS for Oil and Gas Facilities03

    CEMS for Oil and Gas: Refineries and Natural Gas Facilities

    Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
  4. Palm Oil04

    CEMS for Palm Oil Mills

    Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
  5. CEMS for Iron and Steel Mills05

    CEMS for Iron and Steel Mills (Ferrous Metals)

    Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
  6. CEMS for Non-Ferrous Metal Plants06

    CEMS for Non-Ferrous Metal Plants

    Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.