Continuous Emission Monitoring Systems (CEMS)
CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.

This continuous emission monitoring system (CEMS) for cement plants measures sulphur dioxide (SO2), nitrogen dioxide (NO2) and total particulate matter (PM) in stack gas. It is built from extractive gas analysers, in-situ gas analysers and a particulate in-situ analyser, selected to suit the source. Results are collected by a data acquisition system (DAS) and passed through a data interface system (DIS) to the DOE server, so emissions can be checked continuously against the limit values that apply to cement kilns, glass furnaces, rotary furnaces and ceramic furnaces.
Features
- One system covering SO2, NO2 and total PM / dust
- Extractive and in-situ gas analysers, plus a particulate in-situ analyser
- Data acquisition system (DAS) and data interface system (DIS) for reporting
- Sized for cement kilns of all sizes, glass furnaces (≥ 1 ton/day), rotary furnaces (≥ 1 ton/day) and ceramic furnaces (> 10 ton/day)
How it works
- SO2, extractive: NDIR, NDUV, GFC, FTIR, PAS or fluorescence
- SO2, in-situ: DOAS, GFC or FTIR
- NO2, extractive: NDUV, PAS or fluorescence
- NO2, in-situ: DOAS
- Total PM / dust, extractive: light scatter or beta absorption
- Total PM / dust, in-situ: transmissometry or triboelectric, double pass or single pass
Emission limit values
- Cement kiln (all sizes): NO2 800 mg/m³ and total PM 50 mg/m³, at 10% O₂
Glass furnaces, rotary furnaces for quicklime and dolomite, and ceramic furnaces belong to the same non-metallic (mineral) industry sector; their limits are set out on CEMS for glass, ceramic and lime plants.
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data acquisition system (DAS) and data interface system (DIS)
Applications
- Cement kilns
- Glass furnaces, including glass fibre
- Rotary furnaces for quicklime and dolomite
- Ceramic furnaces for tiles, bricks, refractories, stoneware and porcelain
LKS supplies CEMS for cement plants in Malaysia, with installation, calibration and after-sales support. Contact our engineers to scope a system for your stack.
Specifications
| Item | Details |
|---|---|
| Analyser types | Extractive gas analysers; in-situ gas analyser; particulate in-situ analyser |
| Measured parameters | SO2, NO2, total PM / dust |
| SO2 principles | Extractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR |
| NO2 principles | Extractive: NDUV, PAS, fluorescence; in-situ: DOAS |
| Total PM / dust principles | Extractive: light scatter, beta absorption; in-situ: transmissometry / triboelectric, double pass, single pass |
| Data systems | Data acquisition system (DAS); data interface system (DIS) |
| Sources covered | Cement kilns (all sizes); glass furnaces (≥ 1 ton/day); rotary furnaces (≥ 1 ton/day); ceramic furnaces (> 10 ton/day) |
Products
Equipment for this application.

Multigas Analyzer
Multigas analyzers for flue gas and process gas, measuring SO2, NOx, CO, CO2, O2, NH3 and more by UV DOAS, NDIR, TDLAS or electrochemical principles, with Modbus outputs.View range
Dust & Opacity Analyzers
Dust and opacity analyzers for continuous particulate monitoring in stacks and ducts, using transmittance, scattered light, backscatter, extractive and triboelectric principles.View range
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
03CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
04CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
05CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
06CEMS for Non-Ferrous Metal Plants
Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.