Continuous Emission Monitoring Systems (CEMS)

CEMS for Chemical and Petrochemical Plants

Continuous emission monitoring for thermal oxidizers at chemical and petrochemical plants: NO2, NH3, SO2, particulate matter and opacity, measured with UV-DOAS, NDIR and dust and opacity analyzers.

UV-DOAS gas analyzer, MGL series

Chemical and petrochemical plants often treat process off-gases in a thermal oxidizer before release. Where DOE requires these stacks to be monitored continuously, the CEMS must measure the pollutants of the oxidizer exhaust against the limits in the Department of Environment's CEMS guidelines.

When CEMS is required

Unless the Clean Air Regulations 2014 state otherwise, CEMS for a thermal oxidizer at a chemical or petrochemical plant is required on a written directive from DOE.

Emission limit values

PollutantLimit value (mg/m³, at 11% O₂)
Nitrogen dioxide (NO₂)700
Ammonia (NH₃)76
Sulphur dioxide (SO₂)100
Total particulate matter50
Opacity20%

Limits are expressed at standard temperature and pressure for dry gas (273 K, 101.3 kPa).

Measuring the oxidizer exhaust

  • UV-DOAS gas analyzer (MGL series): measures SO₂, NO, NO₂, NH₃, O₂, HCl and other gases on one platform, measures NO and NO₂ at the same time without a converter, is not affected by moisture or dust, and has a detection limit down to 1 mg/m³ for SO₂, NO and NO₂.
  • NDIR gas analyzer (MGL series): a two-beam infrared analyzer for SO₂, NO, CO, CO₂ and related gases, with dual ranges and 4–20 mA and RS485 Modbus outputs.
  • Dust and opacity monitors: in-situ and extractive instruments for particulate matter and opacity.
  • Sampling and data: heated gas sampling probes and sample gas coolers for extractive systems, with a DAS and DIS to report to DOE.

LKS reviews each oxidizer's exhaust composition, temperature and moisture before recommending a configuration. See CEMS data acquisition and DOE reporting for the data chain, or contact our engineers with your stack details for a proposal.

FAQ

Common questions.

All questions
Which plants must install CEMS in Malaysia?

Premises in the source activities listed in the Department of Environment's CEMS guidelines: heat and power generation above 10 MWe, cement and other non-metallic industries, oil and gas facilities, ferrous and non-ferrous metal production, waste incinerators, and fuel burning equipment where the dust emission is 2.5 kg/h or more. Thermal oxidizers at chemical and petrochemical plants need CEMS on a written directive from DOE.

Read next

Related topics.

  1. CEMS for Power Plants01

    CEMS for Power Plants

    Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
  2. CEMS for Cement Plants02

    CEMS for Cement Plants

    Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
  3. CEMS for Oil and Gas Facilities03

    CEMS for Oil and Gas: Refineries and Natural Gas Facilities

    Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
  4. Palm Oil04

    CEMS for Palm Oil Mills

    Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
  5. CEMS for Waste Incinerators05

    CEMS for Waste Incinerators

    Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
  6. CEMS for Iron and Steel Mills06

    CEMS for Iron and Steel Mills (Ferrous Metals)

    Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.