Continuous Emission Monitoring Systems (CEMS)
CEMS for Sugar Mills
Continuous emission monitoring system (CEMS) for sugar mills, combining extractive and in-situ analysers with a particulate in-situ analyser to measure total PM/dust and opacity against the DOE limits of 150 mg/m³ at 12% CO₂ and 20% opacity.

This continuous emission monitoring system (CEMS) for sugar mills measures total particulate matter (PM) and opacity in stack gas. It is built from extractive gas analysers, an in-situ gas analyser and a particulate in-situ analyser, selected to suit the stack. Readings are collected by a data acquisition system (DAS) and passed on through a data interface system (DIS), so the mill can track its emissions continuously against the limit values that apply to sugar mills.
Features
- One system covering total PM / dust and opacity
- Extractive and in-situ analysers, plus a particulate in-situ analyser
- Data acquisition system (DAS) and data interface system (DIS)
How it works
- Total PM / dust, extractive: light scatter or beta absorption
- Total PM / dust, in-situ: transmissometry or triboelectric, double pass or single pass
- Opacity, extractive: light scatter or beta absorption
- Opacity, in-situ: transmissometry or triboelectric, double pass or single pass
Emission limit values
- Opacity: 20%, for any fuel where the total dust emission is 2.5 kg/h or more, or where the smoke is darker than Shade No. 2 on the Ringelmann chart
- Total particulate matter: 150 mg/m³ at 12% CO₂, for solid fuel where the dust load emitted is 2.5 kg/h or more
Because biomass fuel varies from batch to batch, DOE notes that plants burning it may need a QAL2 calibration every year in place of the annual surveillance test.
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data acquisition system (DAS) and data interface system (DIS)
Applications
- Sugar mill boiler stacks
- Continuous dust and opacity reporting
LKS supplies CEMS for sugar mills in Malaysia, with installation, calibration and after-sales support. Contact our engineers to scope a system for your stack.
Specifications
| Item | Details |
|---|---|
| Analyser types | Extractive gas analysers; in-situ gas analyser; particulate in-situ analyser |
| Measured parameters | Total PM / dust, opacity |
| Total PM / dust principles | Extractive: light scatter, beta absorption; in-situ: transmissometry / triboelectric, double pass, single pass |
| Opacity principles | Extractive: light scatter, beta absorption; in-situ: transmissometry / triboelectric, double pass, single pass |
| Data systems | Data acquisition system (DAS); data interface system (DIS) |
| Emission limits (DOE) | Opacity 20%; total PM 150 mg/m³ at 12% CO₂ (solid fuel, dust load ≥ 2.5 kg/h) |
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
05CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
06CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.