Continuous Emission Monitoring Systems (CEMS)

CEMS for Oil and Gas: Refineries and Natural Gas Facilities

Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.

CEMS for Oil and Gas Facilities

This continuous emission monitoring system (CEMS) for oil and gas facilities measures sulphur dioxide (SO2) and total particulate matter (PM) from catalytic cracking and calcination sources. It combines extractive gas analysers, in-situ gas analysers and a particulate in-situ analyser, chosen to suit each stack. Measured data is handled by a data acquisition system (DAS) and a data interface system (DIS), so emissions can be compared continuously with the limit values for refineries, natural gas processing and storage, and the storage and handling of petroleum products.

Features

  • One system covering SO2 and total PM / dust
  • Extractive and in-situ gas analysers, plus a particulate in-situ analyser
  • Data acquisition system (DAS) and data interface system (DIS)
  • Suitable for refineries of all sizes, natural gas processing and storage facilities, and petroleum product storage and handling

How it works

  • SO2, extractive: NDIR, NDUV, GFC, FTIR, PAS or fluorescence
  • SO2, in-situ: DOAS, GFC or FTIR
  • Total PM / dust, extractive: light scatter or beta absorption
  • Total PM / dust, in-situ: transmissometry or triboelectric, double pass or single pass

Emission limit values

  • Catalytic cracking: SO2 1200 mg/m³, total PM 40 mg/m³
  • Calcination: total PM 40 mg/m³

DOE lists these limits for the oil and gas industries source sector, which covers refineries of all sizes, natural gas processing and storage, and the storage and handling of petroleum products.

DOE requirements

  • Supplier listed as an appointed and approved company on the DOE website
  • Data acquisition system (DAS) and data interface system (DIS)

Applications

  • Oil and gas refineries
  • Natural gas processing and storage
  • Storage and handling of petroleum products
  • Catalytic cracking and calcination units

LKS supplies CEMS for oil and gas refineries and natural gas facilities in Malaysia, with installation, calibration and after-sales support. Contact our engineers to scope a system for your source.

Specifications

ItemDetails
Analyser typesExtractive gas analysers; in-situ gas analyser; particulate in-situ analyser
Measured parametersSO2, total PM / dust
SO2 principlesExtractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR
Total PM / dust principlesExtractive: light scatter, beta absorption; in-situ: transmissometry / triboelectric, double pass, single pass
Data systemsData acquisition system (DAS); data interface system (DIS)
Sources coveredCatalytic cracking; calcination

Download the CEMS for Oil and Gas Refineries catalogue (PDF)

Read next

Related topics.

  1. CEMS for Power Plants01

    CEMS for Power Plants

    Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
  2. CEMS for Cement Plants02

    CEMS for Cement Plants

    Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
  3. Palm Oil03

    CEMS for Palm Oil Mills

    Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
  4. CEMS for Waste Incinerators04

    CEMS for Waste Incinerators

    Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
  5. CEMS for Iron and Steel Mills05

    CEMS for Iron and Steel Mills (Ferrous Metals)

    Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
  6. CEMS for Non-Ferrous Metal Plants06

    CEMS for Non-Ferrous Metal Plants

    Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.Read more

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.