Continuous Emission Monitoring Systems (CEMS)

CEMS for Glass, Ceramic and Lime Plants

Continuous emission monitoring system (CEMS) for glass furnaces, ceramic kilns and quicklime or dolomite rotary furnaces, using extractive and in-situ gas analysers and a particulate analyser to measure SO2, NO2 and total PM.

CEMS for Glass, Ceramic and Lime Plants

This continuous emission monitoring system (CEMS) measures sulphur dioxide (SO2), nitrogen dioxide (NO2) and total particulate matter (PM) at the stacks of glass furnaces, ceramic furnaces and rotary furnaces producing hard quicklime or sintered dolomite. Each system is configured from extractive gas analysers, in-situ gas analysers and a particulate in-situ analyser, depending on the source and the pollutants to be reported. Data acquisition (DAS) and data interface (DIS) systems complete the installation, so the plant can report continuous emissions in line with DOE requirements and the limit values for its source category.

Features

  • Measures SO2, NO2 and total PM in one monitoring system
  • Choice of extractive or in-situ gas analysers, plus a particulate in-situ analyser
  • Data acquisition system (DAS) and data interface system (DIS)
  • Covers glass furnaces (> 1 ton/day), rotary furnaces for quicklime and dolomite, and ceramic furnaces (> 10 ton/day)

How it works

  • SO2: NDIR, NDUV, GFC, FTIR, PAS or fluorescence (extractive); DOAS, GFC or FTIR (in-situ)
  • NO2: NDUV, PAS or fluorescence (extractive); DOAS (in-situ)
  • Total PM: light scatter, beta absorption or triboelectric measurement

Emission limit values

  • Glass furnaces, including glass fibre, melting capacity > 1 ton of product per day: SO2 800 mg/m³, NO2 800 mg/m³, total PM 50 mg/m³, at 8% O₂ for flame-heated glass melting furnaces and 13% O₂ for flame-heated pot furnaces and day tanks
  • Ceramic furnaces with production capacity > 10 tons of product per day: total PM 50 mg/m³ at 17% O₂, where the dust load emitted is 2.0 kg/h or more
  • Rotary furnaces for hard quicklime or sintering dolomite: NO2 1500 mg/m³, total PM 50 mg/m³

Cement kilns belong to the same non-metallic (mineral) industry sector and are covered on CEMS for cement plants.

DOE requirements

  • Supplier listed as an appointed and approved company on the DOE website
  • Data acquisition system (DAS) and data interface system (DIS)

Applications

  • Glass and glass fibre manufacturing
  • Ceramic products: roofing tiles, bricks, refractory bricks, ceramic glass, stoneware and porcelain
  • Hard quicklime and sintered dolomite production

LKS supplies CEMS for glass, ceramic and lime plants in Malaysia, with installation, calibration and after-sales support. Contact our engineers to plan a system for your furnace or kiln.

Specifications

ItemDetails
Analyser typesExtractive gas analysers; in-situ gas analyser; particulate in-situ analyser
Measured parametersSO2, NO2, total PM
SO2 principlesExtractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR
NO2 principlesExtractive: NDUV, PAS, fluorescence; in-situ: DOAS
Total PM principlesLight scatter, beta absorption, triboelectric
Data systemsData acquisition system (DAS); data interface system (DIS)
Sources coveredGlass furnaces (> 1 ton/day); rotary furnaces for quicklime and dolomite; ceramic furnaces (> 10 ton/day)

Download the CEMS for Non-Metallic Industries catalogue (PDF)

Read next

Related topics.

  1. CEMS for Power Plants01

    CEMS for Power Plants

    Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
  2. CEMS for Cement Plants02

    CEMS for Cement Plants

    Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
  3. CEMS for Oil and Gas Facilities03

    CEMS for Oil and Gas: Refineries and Natural Gas Facilities

    Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
  4. Palm Oil04

    CEMS for Palm Oil Mills

    Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
  5. CEMS for Waste Incinerators05

    CEMS for Waste Incinerators

    Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
  6. CEMS for Iron and Steel Mills06

    CEMS for Iron and Steel Mills (Ferrous Metals)

    Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.