Continuous Emission Monitoring Systems (CEMS)
CEMS for Glass, Ceramic and Lime Plants
Continuous emission monitoring system (CEMS) for glass furnaces, ceramic kilns and quicklime or dolomite rotary furnaces, using extractive and in-situ gas analysers and a particulate analyser to measure SO2, NO2 and total PM.

This continuous emission monitoring system (CEMS) measures sulphur dioxide (SO2), nitrogen dioxide (NO2) and total particulate matter (PM) at the stacks of glass furnaces, ceramic furnaces and rotary furnaces producing hard quicklime or sintered dolomite. Each system is configured from extractive gas analysers, in-situ gas analysers and a particulate in-situ analyser, depending on the source and the pollutants to be reported. Data acquisition (DAS) and data interface (DIS) systems complete the installation, so the plant can report continuous emissions in line with DOE requirements and the limit values for its source category.
Features
- Measures SO2, NO2 and total PM in one monitoring system
- Choice of extractive or in-situ gas analysers, plus a particulate in-situ analyser
- Data acquisition system (DAS) and data interface system (DIS)
- Covers glass furnaces (> 1 ton/day), rotary furnaces for quicklime and dolomite, and ceramic furnaces (> 10 ton/day)
How it works
- SO2: NDIR, NDUV, GFC, FTIR, PAS or fluorescence (extractive); DOAS, GFC or FTIR (in-situ)
- NO2: NDUV, PAS or fluorescence (extractive); DOAS (in-situ)
- Total PM: light scatter, beta absorption or triboelectric measurement
Emission limit values
- Glass furnaces, including glass fibre, melting capacity > 1 ton of product per day: SO2 800 mg/m³, NO2 800 mg/m³, total PM 50 mg/m³, at 8% O₂ for flame-heated glass melting furnaces and 13% O₂ for flame-heated pot furnaces and day tanks
- Ceramic furnaces with production capacity > 10 tons of product per day: total PM 50 mg/m³ at 17% O₂, where the dust load emitted is 2.0 kg/h or more
- Rotary furnaces for hard quicklime or sintering dolomite: NO2 1500 mg/m³, total PM 50 mg/m³
Cement kilns belong to the same non-metallic (mineral) industry sector and are covered on CEMS for cement plants.
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data acquisition system (DAS) and data interface system (DIS)
Applications
- Glass and glass fibre manufacturing
- Ceramic products: roofing tiles, bricks, refractory bricks, ceramic glass, stoneware and porcelain
- Hard quicklime and sintered dolomite production
LKS supplies CEMS for glass, ceramic and lime plants in Malaysia, with installation, calibration and after-sales support. Contact our engineers to plan a system for your furnace or kiln.
Specifications
| Item | Details |
|---|---|
| Analyser types | Extractive gas analysers; in-situ gas analyser; particulate in-situ analyser |
| Measured parameters | SO2, NO2, total PM |
| SO2 principles | Extractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR |
| NO2 principles | Extractive: NDUV, PAS, fluorescence; in-situ: DOAS |
| Total PM principles | Light scatter, beta absorption, triboelectric |
| Data systems | Data acquisition system (DAS); data interface system (DIS) |
| Sources covered | Glass furnaces (> 1 ton/day); rotary furnaces for quicklime and dolomite; ceramic furnaces (> 10 ton/day) |
Download the CEMS for Non-Metallic Industries catalogue (PDF)
Products
Equipment for this application.

Multigas Analyzer
Multigas analyzers for flue gas and process gas, measuring SO2, NOx, CO, CO2, O2, NH3 and more by UV DOAS, NDIR, TDLAS or electrochemical principles, with Modbus outputs.View range
Dust & Opacity Analyzers
Dust and opacity analyzers for continuous particulate monitoring in stacks and ducts, using transmittance, scattered light, backscatter, extractive and triboelectric principles.View range
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
05CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
06CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.