Continuous Emission Monitoring Systems (CEMS)
CEMS for Non-Ferrous Metal Plants
Continuous emission monitoring system (CEMS) for sinter plants and non-ferrous metal production, using extractive and in-situ gas analysers and a particulate in-situ analyser to measure SO2, NO2 and total PM/dust.

This continuous emission monitoring system (CEMS) for non-ferrous metal plants measures sulphur dioxide (SO2), nitrogen dioxide (NO2) and total particulate matter (PM) in stack and process exhaust gas. It combines extractive gas analysers, in-situ gas analysers and a particulate in-situ analyser, chosen for each source, from waste gas off a sintering belt to copper, zinc, lead and aluminium production. A data acquisition system (DAS) and data interface system (DIS) record the readings and pass them to the DOE server for compliance with the emission limit values.
Features
- Monitors SO2, NO2 and total PM / dust continuously
- Extractive and in-situ gas analysers, plus a particulate in-situ analyser
- Data acquisition system (DAS) and data interface system (DIS)
- Configured for sinter plants and for copper, zinc, lead and aluminium production
How it works
- SO2: NDIR, NDUV, GFC, FTIR, PAS or fluorescence (extractive); DOAS, GFC or FTIR (in-situ)
- NO2: NDUV, PAS or fluorescence (extractive); DOAS (in-situ)
- Total PM / dust: light scatter or beta absorption (extractive); transmissometry or triboelectric, double pass or single pass (in-situ)
Emission limit values
For production and processing of non-ferrous metals with a capacity of more than 0.5 tons per day for lead or cadmium, or more than 2 tons per day for other metals:
- Sinter plants (waste gas from the sintering belt): SO2 500 mg/m³, NO2 400 mg/m³, total PM 50 mg/m³
- Production of copper and zinc: total PM 20 mg/m³
- Production of lead: total PM 10 mg/m³
- Primary aluminium: SO2 100 mg/m³, total PM 10 mg/m³
- Secondary aluminium: total PM 10 mg/m³
- Smelting, alloying and refining of aluminium: total PM 10 mg/m³
- Smelting, alloying and refining of other non-ferrous metals: total PM 5 mg/m³
Sinter plants in iron and steel production are covered on CEMS for iron and steel mills.
DOE requirements
- Supplier listed as an appointed and approved company on the DOE website
- Data acquisition system (DAS) and data interface system (DIS)
Applications
- Sinter plants
- Copper and zinc production
- Lead production
- Primary and secondary aluminium production
- Smelting, alloying and refining of non-ferrous metals
LKS supplies CEMS for non-ferrous metal plants in Malaysia, with installation, calibration and after-sales support. Contact our engineers to scope a system and request a quotation.
Specifications
| Item | Details |
|---|---|
| Analyser types | Extractive gas analysers; in-situ gas analyser; particulate in-situ analyser |
| Measured parameters | SO2, NO2, total PM / dust |
| SO2 principles | Extractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR |
| NO2 principles | Extractive: NDUV, PAS, fluorescence; in-situ: DOAS |
| Total PM / dust principles | Extractive: light scatter, beta absorption; in-situ: transmissometry / triboelectric, double pass, single pass |
| Data systems | Data acquisition system (DAS); data interface system (DIS) |
| Sources covered | Sinter plants; copper and zinc production; lead production; primary and secondary aluminium; smelting, alloying and refining of non-ferrous metals |
Download the CEMS for Iron and Steel Mills (Non-Ferrous Metals) catalogue (PDF)
Products
Equipment for this application.

Multigas Analyzer
Multigas analyzers for flue gas and process gas, measuring SO2, NOx, CO, CO2, O2, NH3 and more by UV DOAS, NDIR, TDLAS or electrochemical principles, with Modbus outputs.View range
Dust & Opacity Analyzers
Dust and opacity analyzers for continuous particulate monitoring in stacks and ducts, using transmittance, scattered light, backscatter, extractive and triboelectric principles.View range
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
05CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
06CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.