Continuous Emission Monitoring Systems (CEMS)
CEMS for Saw Mills
Continuous emission monitoring system (CEMS) for saw mill stacks that measures total particulate matter and opacity with extractive or in-situ dust and opacity analysers, sending data to the DOE server.

This continuous emission monitoring system (CEMS) is configured for saw mills, where the monitored pollutants are total particulate matter (PM) and opacity. Dust and opacity are measured at the stack by in-situ analysers such as triboelectric and double-pass instruments, or by extractive analysers using light scatter or beta absorption. Analyser signals travel over 4–20 mA lines to a CEMS data interface system (DIS) computer, which forwards the data to the DOE server over TCP/IP. The system can also include extractive and in-situ gas analysers where further measurements are needed.
Features
- Measures total PM/dust and opacity
- Choice of extractive or in-situ dust and opacity analysers
- Extractive and in-situ gas analysers available in the same system
- Data acquisition system (DAS) and data interface system (DIS)
- 4–20 mA analyser signals and TCP/IP link to the DOE server
How it works
- Total PM/dust, extractive: light scatter or beta absorption
- Total PM/dust, in-situ: transmissometry or triboelectric, double pass or single pass
- Opacity, extractive: light scatter or beta absorption
- Opacity, in-situ: transmissometry or triboelectric, double pass or single pass
Emission limit values
- Opacity: 20%, for any fuel where the total dust emission is 2.5 kg/h or more, or where the smoke is darker than Shade No. 2 on the Ringelmann chart
- Total particulate matter: 150 mg/m³ at 12% CO₂, for solid fuel where the dust load emitted is 2.5 kg/h or more
Because biomass fuel varies from batch to batch, DOE notes that plants burning it may need a QAL2 calibration every year in place of the annual surveillance test.
Applications
- Saw mill stacks
- Dust and opacity monitoring for DOE reporting
LKS supplies CEMS for saw mills in Malaysia, with installation, calibration and after-sales support. Contact our engineers for system design and a quotation.
Specifications
| Item | Details |
|---|---|
| Measured parameters | Total PM/dust, opacity |
| Analyser types | Extractive gas analysers, in-situ gas analyser, in-situ particulate analyser |
| Total PM/dust principle | Extractive: light scatter, beta absorption; in-situ: transmissometry/triboelectric, double pass, single pass |
| Opacity principle | Extractive: light scatter, beta absorption; in-situ: transmissometry/triboelectric, double pass, single pass |
| Signal and data | 4–20 mA to CEMS-DIS; TCP/IP to DOE server |
| Data systems | Data acquisition system (DAS), data interface system (DIS) |
| Emission limits (DOE) | Opacity 20%; total PM 150 mg/m³ at 12% CO₂ (solid fuel, dust load ≥ 2.5 kg/h) |
Read next
Related topics.
01CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.Read more
02CEMS for Cement Plants
Continuous emission monitoring system (CEMS) for cement kilns and related non-metallic sources, combining extractive and in-situ gas analysers with a particulate in-situ analyser to measure SO2, NO2 and total PM/dust against DOE emission limits.Read more
03CEMS for Oil and Gas: Refineries and Natural Gas Facilities
Continuous emission monitoring system (CEMS) for oil and gas refineries and natural gas processing and storage facilities, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2 and total PM.Read more
04CEMS for Palm Oil Mills
Continuous emission monitoring system (CEMS) for palm oil mills, combining extractive gas analyzers, in-situ gas analyzers and particulate in-situ analyzers to measure total PM/dust and opacity, with data sent to the DOE server.Read more
05CEMS for Waste Incinerators
Continuous emission monitoring system (CEMS) for waste incinerators of all sizes, combining extractive and in-situ gas analysers with an in-situ particulate analyser to measure total PM, NMVOC, HCl, HF, SO2, NO2 and CO against DOE emission limits.Read more
06CEMS for Iron and Steel Mills (Ferrous Metals)
Continuous emission monitoring system for iron and steel mills, combining extractive gas analysers, in-situ gas analysers and in-situ particulate analysers to measure SO2, NO2 and total PM from sinter plants, coke ovens and furnaces.Read more
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.