Single Parameter Gas Analyzer

VOC Gas Analyzer LK-1000F

Model LK-1000F

LK-1000F VOC gas analyser with a built-in photoionisation (PID) sensor and suction pump, measuring VOC from 0 to 6000 ppm with ±2% F.S. accuracy and 2 s response, in a compact IP66 weatherproof panel with RS485 Modbus RTU.

Overview

About the VOC Gas Analyzer LK-1000F.

The LK-1000F VOC gas analyser measures the concentration of volatile organic compounds in sample gas using the photoionisation detection (PID) method. A built-in suction pump draws the sample at 1.0 l/min to the PID sensor, which gives a single-parameter VOC reading from 0 to 6000 ppm with ±2% F.S. accuracy and a 2 s response time. The analyser is built into a compact IP66 weatherproof panel enclosure with an LCD display and RS485 Modbus RTU communication. Typical uses are VOC analysis and leak detection at gas stations, landfills, sewerage and wastewater treatment plants, and anaerobic digestion and other fermentation processes.

Features

  • Photoionisation detection (PID) sensor, built in
  • VOC range 0 … 6000 ppm, single parameter
  • Accuracy ±2% F.S., response time 2 s
  • Sampling with built-in suction pump, 1.0 l/min
  • LCD display
  • RS485 Modbus RTU communication
  • IP66 weatherproof panel enclosure with compact dimensions
  • Calibration with standard gas; 5 min warm-up

Applications

  • Gas stations
  • Landfills
  • Sewerage and wastewater treatment plants
  • Water treatment plants
  • Oil and gas platforms
  • Chemical plants
  • Anaerobic digestion and fermentation processes

LKS supplies the LK-1000F VOC gas analyser in Malaysia, with installation, calibration and after-sales support. Contact our engineers for application advice and a quotation.

  • Gas analysis
  • Gas detection
  • Online analyzer
  • MODBUS
  • Oil & gas

Specifications

ModelLK-1000F
Measuring principlePhotoionisation detection (PID)
ParameterVOC, single parameter
Measuring range0 … 6000 ppm
Accuracy±2% F.S.
Response time2 s
Warm-up time5 min
CalibrationStandard gas
SamplingSuction pump, 1.0 l/min
DisplayLCD
CommunicationRS485 Modbus RTU
Power supply230 V AC, 50/60 Hz
Ambient temperature−10 … 100 °C
EnclosureIP66 weatherproof panel

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.