VOC Gas Analyzer FID
Model GFID
VOC gas analyzer (GFID) that separates volatile organic compounds on a heated chromatographic column and measures them with a flame ionisation detector, from 0.01 to 1000 ppm (as methane) with 0.001 ppm resolution and RS485 Modbus RTU output.
Overview
About the VOC Gas Analyzer FID GFID.
The GFID VOC gas analyzer measures volatile organic compounds using gas chromatography with a flame ionisation detector (FID), one of the effective methods for detecting low concentrations of organic gas. The analyzer works at high temperature: an air bath heating chamber keeps the chromatographic column and the gas paths before and after it hot. The multi-component sample passes through the special packing of the column and is separated as it flows out. A carrier gas then delivers each component to the FID, where the hydrogen flame ionises the molecules and the released electrons generate a signal current proportional to the quantity of gas entering the detector.
Features
- Measuring range 0.01 … 1000 ppm (as methane) with 0.001 ppm resolution
- Automatic back-flushing of the chromatographic column to speed up separation and analysis
- Inert-treated gas lines prevent adsorption and sample residue on the pipe walls
- Configuration supports multiple detectors for complex sample analysis at the same time
- Touch screen LCD
- Ethernet and RS232 ports; RS485 Modbus RTU, GSM and Wi-Fi communication
How it works
- Air bath heating chamber keeps the column and gas paths at high temperature
- Chromatographic column separates the multi-component gas mixture
- Carrier gas transports the separated components to the FID
- Hydrogen flame ionises the molecules; the high-voltage field collects the electrons as a measurable current
Applications
- Crude oil processing
- Textile and dyeing
- Chemical and pharmaceutical plants
- Metal smelting
- Food and beverage industries
LKS supplies the GFID VOC gas analyzer in Malaysia, with installation, calibration and after-sales support. Contact our engineers for application sizing and a quotation.
Specifications
| Model | GFID |
|---|---|
| Measuring principle | FID (flame ionisation detector) with chromatographic column |
| Measuring range | 0.01 … 1000 ppm (as methane) |
| Resolution | 0.001 ppm |
| Range drift | ≤ 3.0% (4 h) |
| Linearity | < 4% above measurement range |
| Sample gas input flow | 200 mL/min |
| Display | Touch screen LCD |
| Communication output | 10/100M Ethernet port, RS232 |
| Communication protocol | RS485 Modbus RTU / GSM / Wi-Fi |
| Power supply | 230 VAC, 50/60 Hz, 900 W |
| Power consumption | 500 W |
| Ambient temperature | −5 … 40 °C |
| Size | 500 × 500 × 210 mm |
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Related products
Single Parameter Gas AnalyzerLaser Extractive Gas AnalyzerView details
Single Parameter Gas AnalyzerMercury Gas AnalyzerView details
Single Parameter Gas AnalyzerVOC Gas Analyzer LK-1000FView details
Multigas AnalyzerUV DOAS Gas AnalyzerView details
Dust & Opacity AnalyzersDust & Opacity Analyzer (Single Pass)View details
Dust & Opacity AnalyzersBackscatter Light Dust Monitor D10.8View details
Full SystemCEMS for Cement PlantsView details
Continuous Emission Monitoring SystemCEMS AccessoriesView details
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.