Single Parameter Gas Analyzer

Mercury Gas Analyzer

Model GHg

Mercury gas analyzer (GHg) using cold vapour atomic fluorescence spectrophotometry (CV-AFS) to monitor elemental, ionic and total gaseous mercury in stack emissions in real time, with a detection limit down to 0.05 µg/m³.

Overview

About the Mercury Gas Analyzer GHg.

The GHg mercury gas analyzer is a continuous emission monitoring system based on cold vapour atomic fluorescence spectrophotometry (CV-AFS). It measures the real-time concentration of mercury in flue gas together with its cumulative emission rate, and can monitor gaseous elemental mercury, ionic mercury and total gaseous mercury. Mercury compounds are catalytically converted at 800 °C before measurement, and the detection limit is as low as 0.05 µg/m³. The system is used to measure mercury in the tail gas of industries such as mercury mineral refining, mercuric chloride catalyst recycling and coal-fired power plants.

Features

  • CV-AFS measurement technology with high measurement accuracy
  • Samples untreated gas at large flow, with strong resistance to adsorption
  • Combined internal and external purge for long maintenance intervals
  • Real-time monitoring of the dilution ratio, reflecting true working conditions
  • Mercury valence states catalysed and converted at 800 °C, with a conversion rate of up to 95%
  • Measuring range from 0–10 µg/m³ up to 200 µg/m³, customisable
  • Indication error ≤ ±5% and repeatability ≤ ±1%

Applications

  • Coal-fired and waste-to-energy power plants
  • Aluminium plants, steel mills and smelting
  • Glass factories and cement plants
  • Chemical plants, mercury mineral refining and mercuric chloride catalyst recycling
  • Ammonia slip emission monitoring

LKS supplies the GHg mercury gas analyzer in Malaysia, with installation, calibration and after-sales support. Contact our engineers for system sizing and a quotation.

  • CEMS
  • Gas analysis
  • Online analyzer
  • Power plants

Specifications

ModelGHg
Measuring principleCold vapour atomic fluorescence spectrophotometry (CV-AFS)
Measured componentsGaseous elemental mercury, ionic mercury, total gaseous mercury
Range0 … 10 µg/m³ to 200 µg/m³ (customisable)
Detection limit0.05 µg/m³
Indication error≤ ±5%
Repeatability≤ ±1%
Stability≤ ±1%
Zero drift≤ ±1% F.S.
Span drift≤ ±1% F.S.
ConversionCatalytic conversion at 800 °C, conversion rate up to 95%
Size800 × 600 × 1800 mm
Power230 VAC, 5000 W
Working temperature−20 … 50 °C
Working humidity0 … 95% RH (non-condensing)

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.