
CEMS for Power Plants
Continuous emission monitoring system (CEMS) for power plant boilers and combustion turbines above 10 MWe, combining extractive and in-situ gas analysers with a particulate analyser to measure SO2, NO2, CO and total PM.
Overview
About the CEMS for Power Plants.
This continuous emission monitoring system (CEMS) is configured for heat and power generation, covering boilers and combustion turbines above 10 MWe firing liquid, solid or gas fuel. It measures sulphur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO) and total particulate matter at the stack. Depending on the source, the system combines extractive gas analysers fed through a sampling probe and heated line, in-situ gas analysers mounted on the stack, and an in-situ particulate analyser. Analyser signals reach a CEMS data interface system (DIS) computer over 4–20 mA lines, and the data is passed on to the DOE/EPA server over TCP/IP.
Features
- Extractive gas analysers, in-situ gas analysers and in-situ particulate analysers
- Measures SO2, NO2, CO and total PM/dust
- Sampling probe and heated sample line for extractive measurement
- Triboelectric and double-pass in-situ dust measurement
- Data acquisition system (DAS) and data interface system (DIS)
- Data link to the DOE/EPA server over TCP/IP
How it works
- SO2: NDIR, NDUV, GFC, FTIR, PAS or fluorescence (extractive); DOAS, GFC or FTIR (in-situ)
- NO2: NDUV, PAS or fluorescence (extractive); DOAS (in-situ)
- CO: NDIR, GFC, FTIR or PAS (extractive); DOAS, GFC, FTIR or TDL (in-situ)
- Total PM/dust: light scatter or beta absorption (extractive); transmissometry, triboelectric, double pass or single pass (in-situ)
Emission limit values
- Boilers > 10 MWe, liquid and solid fuel: SO2 500, NO2 500, CO 200, total PM 50 mg/m³
- Boilers > 10 MWe, gas fuel: NO2 350, CO 50 mg/m³
- Combustion turbines > 10 MWe, gas fuel: NO2 150, CO 100 mg/m³
- Combustion turbines > 10 MWe, liquid fuel: NO2 200, CO 100 mg/m³
Applications
- Power plant boilers above 10 MWe
- Gas- and liquid-fuelled combustion turbines above 10 MWe
- Heat and power generation stacks
LKS supplies CEMS for power plants in Malaysia, with installation, calibration and after-sales support. Contact our engineers for system design and a quotation.
Specifications
| Source capacity | Boilers > 10 MWe (liquid, solid or gas fuel); combustion turbines > 10 MWe (gas or liquid fuel) |
|---|---|
| Analyser types | Extractive gas analysers, in-situ gas analysers, in-situ particulate analyser |
| Measured parameters | SO2, NO2, CO, total PM/dust |
| SO2 principle | Extractive: NDIR, NDUV, GFC, FTIR, PAS, fluorescence; in-situ: DOAS, GFC, FTIR |
| NO2 principle | Extractive: NDUV, PAS, fluorescence; in-situ: DOAS |
| CO principle | Extractive: NDIR, GFC, FTIR, PAS; in-situ: DOAS, GFC, FTIR, TDL |
| Total PM/dust principle | Extractive: light scatter, beta absorption; in-situ: transmissometry/triboelectric, double pass, single pass |
| Signal and data | 4–20 mA to CEMS-DIS; TCP/IP to DOE/EPA server |
| Data systems | Data acquisition system (DAS), data interface system (DIS) |
| Emission limits, boilers > 10 MWe (liquid/solid fuel) | SO2 500, NO2 500, CO 200, total PM 50 mg/m³ |
| Emission limits, boilers > 10 MWe (gas fuel) | NO2 350, CO 50 mg/m³ |
| Emission limits, combustion turbines > 10 MWe (gas fuel) | NO2 150, CO 100 mg/m³ |
| Emission limits, combustion turbines > 10 MWe (liquid fuel) | NO2 200, CO 100 mg/m³ |
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Related products
Full SystemCEMS for Cement PlantsView details
Full SystemCEMS for Iron and Steel Mills (Ferrous Metals)View details
Full SystemCEMS for Iron and Steel Mills (Non-Ferrous Metals)View details
Full SystemCEMS for Non-Metallic IndustriesView details
Full SystemCEMS for Oil and Gas RefineriesView details
Full SystemCEMS for Palm Oil MillsView details
Full SystemCEMS for Rice MillsView details
Full SystemCEMS for Saw MillsView details
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.