• Electrochemical Gas Analyzer

Multigas Analyzer

Electrochemical Gas Analyzer

Model MGL

MGL series electrochemical (ECD) gas analyser for stack and process gas monitoring, with ±1% F.S. accuracy, 2 s response time, 4–20 mA output and RS485 Modbus RTU, in a 19-inch 4U or wall-mount panel.

Overview

About the Electrochemical Gas Analyzer MGL.

The MGL series electrochemical gas analyser measures gas concentration with ECD sensors for emission and process monitoring. Gas diffuses into the sensor through a small capillary opening and a hydrophobic barrier to reach the electrode surface, where it is oxidised or reduced. This reaction produces an electrical signal proportional to the gas concentration. The analyser is built in a 19-inch 4U panel or a wall-mount panel, gives an accuracy of ±1% F.S. with a 2 s response time, and reports through a 4–20 mA analogue output and RS485 Modbus RTU for connection to plant control or data systems.

Features

  • Electrochemical (ECD) measuring principle
  • Accuracy ±1% F.S., resolution 0.01%
  • Response time 2 s
  • Repeatability ±2% F.S., linearity ±2% F.S.
  • Zero/span drift ±1% F.S.
  • 4–20 mA analogue output and RS485 Modbus RTU
  • 19-inch 4U panel or wall-mount panel
  • 800 × 480 display

How it works

  • Gas enters the sensor through a small capillary-type opening
  • It diffuses through a hydrophobic barrier to the electrode surface
  • The gas is oxidised or reduced at the sensing electrode
  • The resulting electrical signal is proportional to the gas concentration

Applications

  • Waste-to-energy (garbage) power plants
  • Coal-fired power plants
  • Desulphurisation systems
  • Coke ovens
  • Ceramic factories

LKS supplies the MGL electrochemical gas analyser in Malaysia, with installation, calibration and after-sales support. Contact our engineers for gas selection and a quotation.

  • Gas analysis
  • CEMS
  • Online analyzer
  • MODBUS
  • Power plants

Specifications

ModelMGL series
Measuring principleElectrochemical (ECD)
Accuracy±1% F.S.
Repeatability±2% F.S.
Linearity±2% F.S.
Zero/span drift±1% F.S.
Resolution0.01%
Response time2 s
Humidity0 … 40%
Analogue output4–20 mA
CommunicationRS485 Modbus RTU
Power supply230 V AC, 50/60 Hz
Housing19-inch 4U panel or wall-mount panel

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.