Turbidity/Total Suspended Solids

WSTB1003 Low Range Turbidity Sensor

Model WSTB1003

WSTB1003 low range online turbidity sensor with flow-through installation and 90° light scattering, measuring 0–20.00 NTU with zero drift below 0.015 NTU, RS485 Modbus RTU output and 24 VDC supply, for drinking water and pure water.

Brand
TGI German Technologies

Overview

About the WSTB1003 Low Range Turbidity Sensor.

The WSTB1003 low range turbidity sensor is an industrial online sensor with a flow-through installation, used to monitor turbidity in clean and treated water. It works on the light scattering principle: as the water sample passes through the sensor, a light beam penetrates the water and is scattered by the particles present, and a detector placed at 90° to the light source measures the scattered light. More particles scatter more light and give a higher turbidity reading. Because it keeps high accuracy in the low range up to 20 NTU, it can be used for drinking water after membrane purification.

Features

  • Low range 0 … 20.00 NTU with high accuracy, suitable for drinking water after membrane water purification
  • Zero drift below 0.015 NTU
  • Small size, convenient for system integration
  • Low water consumption, flow rate up to 300 ml/min
  • Long maintenance cycle with automatic sewage discharge
  • Wiper keeps the measuring surface clean for accurate readings
  • RS485 Modbus RTU digital output, 24 VDC supply

How it works

  • Flow-through cell: the water sample passes through the sensor
  • Light source: a beam penetrates the sample and is scattered by particles
  • Detector at 90°: measures the scattered light, which rises with turbidity

Applications

  • Power plants
  • Pure water plants
  • Tap water plants
  • Sewage treatment plants
  • Beverage plants
  • Environmental protection departments
  • Industrial water and the liquor industry
  • Pharmaceutical industry
  • Epidemic prevention departments and hospitals

LKS supplies the WSTB1003 low range turbidity sensor in Malaysia, with installation, calibration and after-sales support. Contact our engineers for application advice and a quotation.

  • Turbidity
  • Water quality
  • Optical
  • MODBUS
  • Water & wastewater

Specifications

ModelWSTB1003
Measuring principleLight scattering, detector at 90° to the light source
InstallationFlow-through
Measuring range0 … 20.00 NTU
Accuracy< ±2% FS
Zero drift< 0.015 NTU
Calibration methodFormazin standard solution calibration
Applicable temperature0 … 50 °C
Sample flow rateNot more than 300 ml/min
Digital outputRS485 Modbus RTU
Power supply24 VDC
Dimensions293 (h) × 184 (w) × 123 (d) mm

Lifecycle support

Installed, calibrated and maintained.

With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.

  • Installation & commissioning
  • Calibration & testing
  • Maintenance & overhaul
  • Dismantling & replacement

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.