Turbidity/Total Suspended Solids
WMTS1001 TSS Meter
Model WMTS1001
WMTS1001 industrial turbidity / TSS meter for continuous monitoring of suspended solids, with ±2% accuracy, ranges to 120 g/L, one month of stored history, isolated 4–20 mA output, alarm relays, RS485 Modbus RTU and an IP65 panel case.
- Brand
- TGI German Technologies
- Category
- Turbidity/Total Suspended Solids
Overview
About the WMTS1001 TSS Meter.
The WMTS1001 TSS meter is an industrial turbidity and total suspended solids (TSS) transmitter for continuous online monitoring. It works with a high-precision A/D converter and single-chip microprocessor, and shows turbidity, output current, time and status on one screen with full English menus. The meter logs a reading automatically every 5 minutes and keeps one month of turbidity data as a history curve. Photoelectric isolation on the current output gives strong interference immunity and long transmission distances, and the IP65 case is suitable for outdoor use. It is used in water plants, water treatment, thermal power plants, pharmaceutical plants and hospitals.
Features
- Measuring range specified when ordering: 0 … 99999.0 mg/L or 99.99 … 120.0 g/L
- Accuracy ±2%
- Multi-parameter display: turbidity, output current, time and status on one screen
- English display and menu operation
- History curve: data saved every 5 minutes, with one month of turbidity data stored
- Automatic measurement switching and instrument self-check
- Photoelectric isolation on the 4–20 mA output, with high electromagnetic compatibility
- RS485 interface with Modbus RTU for connection to a computer
- Waterproof and dustproof IP65 design for outdoor installation
Applications
- Water plants and water treatment
- Thermal power plants
- Pharmaceutical plants
- Hospitals
LKS supplies the WMTS1001 TSS meter in Malaysia, with installation, calibration and after-sales support. Contact our engineers to specify the measuring range and request a quotation.
Specifications
| Model | WMTS1001 |
|---|---|
| Measuring range (specified when ordering) | 0 … 99999.0 mg/L; 99.99 … 120.0 g/L |
| Accuracy | ±2% |
| Isolated current output | 4–20 mA (load < 750 Ω) |
| Communication | RS485 (optional), Modbus RTU |
| Alarm relay | 5 A / 250 VAC; 5 A / 30 VDC |
| Data logging | Every 5 minutes; one month of turbidity data |
| Power supply | 230 VAC, 50/60 Hz |
| Protection class | IP65 |
| Material | ABS |
| Dimensions | 144 × 144 × 104 mm (L × W × D); panel cut-out 138 × 138 mm |
| Weight | 0.9 kg |
| Working conditions | Ambient 0 … 60 °C; relative humidity < 85% |
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Related products
Turbidity/Total Suspended SolidsWMTB1001 Turbidity MeterView details
Turbidity/Total Suspended SolidsWSTB1002 High Range Turbidity SensorView details
Turbidity/Total Suspended SolidsWSTB1003 Low Range Turbidity SensorView details
Turbidity/Total Suspended SolidsWSTS1001 TSS SensorView details
pHWMPH1001-FM pH MeterView details
ConductivityIndustrial Conductivity SensorsView details
Dissolved OxygenDSMD1900 Digital DO SensorView details
pHDSMG1310T Digital pH SensorView details
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.