Mechanical Level Indicator R3
Model R3
Mechanical level indicator R3 with a large round dial that shows water level in reservoirs and suction tanks by float, string and counterweight, with 1% of full scale accuracy, ranges up to 0–30 m and a mild steel case, galvanised or epoxy coated.
Overview
About the Mechanical Level Indicator R3.
The R3 mechanical level indicator shows the water level of reservoirs, suction tanks and similar vessels on a large round dial. A float on the liquid surface is connected by a string over a pulley to a counterweight; as the level changes, the movement turns a gear and shaft that drive the pointer across the dial. The scale and range are selected to suit each tank, in metres or feet, and the mild steel housing is either hot-dipped galvanised or epoxy coated. An optional 4–20 mA loop signal allows the level to be transmitted to a control system.
Features
- Dial sizes from 300 mm to 1500 mm (12" to 60")
- Accuracy of 1% of full scale; zero stability and repeatability ±0.5% of full scale
- Level ranges from 0–3 m up to 0–30 m, or ranges in feet
- Mild steel casing with hot-dipped galvanised or epoxy coating
- Reflective text name plate and optional luminous dial marking
- Optional back cover and stand
- Optional 4–20 mA loop transmit signal (24 VDC)
How it works
- A PVC or stainless steel float follows the liquid surface
- The string runs over a pulley to a brass, cement or stainless steel counterweight
- A brass or stainless steel gear and shaft turn the pointer on the dial
Options
- Float: PVC (standard) or stainless steel SS316
- Rope: nylon-coated stainless steel or nylon, supplied per 10 m roll to suit the range
- Gear and shaft: brass (standard) or stainless steel
- Standard model LI-H24M1024PR1BTX0: 24" dial, hot-dipped galvanised, 0–10 m, reflex text name plate, PVC float, brass weight, back cover and stand
Applications
- Reservoirs
- Suction tanks
- Water tanks and other non-aggressive fluids
LKS supplies the R3 mechanical level indicator in Malaysia, with installation, calibration and after-sales support. Contact our engineers with your tank height and preferred dial size for a quotation.
Specifications
| Order code prefix | LI- |
|---|---|
| Dial size | 300, 400, 600, 900 mm; 1200 and 1500 mm (48", 60") in order codes |
| Indication unit | Metres or feet |
| Level range | 0–3, 0–4, 0–5, 0–6, 0–8, 0–10 (standard), 0–15, 0–20, 0–30 m; ranges in feet available |
| Accuracy | 1% of full scale |
| Zero stability | ±0.5% of full scale |
| Repeatability | ±0.5% of full scale |
| Working temperature | Up to 80 °C |
| Relative humidity | 90% RH |
| Casing and bracket | Mild steel with epoxy coating or hot-dipped galvanised |
| Gear | Brass or stainless steel |
| Pulley | Aluminium |
| String | Nylon or stainless steel coated |
| Counterweight | Brass, stainless steel or cement |
| Float | PVC or stainless steel |
| Overall size A / D (300 mm dial) | 400 mm / 470 mm |
| Overall size A / D (400 mm dial) | 500 mm / 622 mm |
| Overall size A / D (600 mm dial) | 700 mm / 857 mm |
| Overall size A / D (900 mm dial) | 1000 mm / 1168 mm |
| Optional output | 4–20 mA loop signal (24 VDC) |
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Related products
Level TransmitterRadar Level TransmitterView details
Level GaugeMagnetic Bypass Level GaugeView details
Level GaugeBi Colour Level GaugeView details
Level SwitchCapacitive Level Switch CLSView details
Level TransmitterCompact Pressure TransmitterView details
Submersible Level TransmitterElectronic Submersible Level TransmitterView details
Level SwitchFloat-Less Water Level ControlView details
Level SwitchFloat Level Switch 506View details
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.