Class I Surge Protection Device LP-50A
Model LP-50A
LP-50A Class I surge protection device for the low-voltage side of 230/400 V transformers or the LPZ0–LPZ1 boundary, with 25 kA impulse discharge current (10/350 µs), < 2.0 kV protection level and 2P to 4P combinations.
- Category
- Surge Protection Devices
Overview
About the Class I Surge Protection Device LP-50A.
The LP-50A is a Class I surge protection device fitted on the low-voltage side of a transformer with a rated working voltage of 230/400 V, or at the boundary between lightning protection zones LPZ0 and LPZ1. It protects the installation against overvoltage caused by lightning or surges. Built-in multi-gap construction gives a large current capacity and a low residual voltage in a fully enclosed housing with no arc escape. The device is not intended for systems whose expected short-circuit current exceeds its rated breaking follow current, and a backup fuse must be connected on its supply side.
Features
- Impulse discharge current Iimp 25 kA (10/350 µs) with a voltage protection level below 2.0 kV
- Large current capacity, low residual voltage, totally enclosed structure with no arc escape
- Built-in multi-gap design with a strong ability to extinguish follow current
- Protection modes L-N, L-PE and N-PE
- Combinations 2P, 3P, 4P and 3P+NPE for different power networks
- Flame-retardant reinforced nylon housing (UL 94V-0)
- 100 ns response time
Applications
- Low-voltage side of 230/400 V distribution transformers
- Main incoming supplies at the LPZ0 / LPZ1 zone boundary
- Class I lightning and surge protection of low-voltage power networks
LKS supplies the LP-50A surge protection device in Malaysia, with installation and after-sales support. Contact our engineers for protection-scheme selection and a quotation.
Specifications
| Model | LP-50A |
|---|---|
| Class | Class I |
| Rated working voltage | 230/400 V |
| Max. continuous operating voltage | 320 V |
| Voltage protection level Up | < 2.0 kV |
| Impulse discharge current Iimp (10/350 µs) | 25 kA |
| Response time | 100 ns |
| Protection modes | L-N, L-PE, N-PE |
| Combination mode | 2P, 3P, 4P, 3P+NPE |
| Insulation resistance | > 5 MΩ |
| Max. backup fuse (if mains > 250 A) | 250 A gL |
| Recommended grounding conductor | 16 mm² multi-strand flexible wire |
| Housing material | Flame-retardant reinforced nylon (UL 94V-0) |
| Dimensions (drawing) | 36 mm width per pole (1P 36, 2P 72, 3P 108, 4P 144 mm); 93 mm height; 66.5 mm depth |
Lifecycle support
Installed, calibrated and maintained.
With more than two decades in valves and instrumentation across a diverse range of industries, we keep instruments accurate and valves healthy, because valve health management is vital for plant safety.
- Installation & commissioning
- Calibration & testing
- Maintenance & overhaul
- Dismantling & replacement
Related products
Surge Protection DevicesClass C Power Surge Protector LP-20CView details
Surge Protection DevicesClass B+C Power Surge Protector LP-40B+CView details
Surge Protection DevicesPower Class B Surge Protector LP-75BView details
Surge Protection DevicesBNC Video Signal Surge Protector LP-C/BNC/LView details
Surge Protection DevicesCCTV BNC Surge Protector LP-C/BNCView details
Surge Protection DevicesDB9 Signal Lightning Protector LP-C/DB9View details
Surge Protection DevicesAluminium RJ45 Network Surge Protector LP-C/RJ45/LView details
Surge Protection DevicesEthernet Surge Protector LP-C/RJ45/SView details
Get in touch
Need a quote or technical advice?
Tell us about your application and our engineers will recommend the right instrument or system.
- 01Share your applicationProcess, medium, range and site conditions.
- 02Engineer recommendationWe match the right instrument or system to your process.
- 03Quotation and supportSupply, installation, calibration and after-sales service.