Flow measurement

Coriolis Mass Flow Meter Selection: A Practical Guide

Choose a Coriolis meter by checking fluid phase, flow range, pressure drop, required outputs and installation conditions before requesting a process-specific recommendation.

Text 1/3
Stainless-steel pipes run between clean industrial buildings beneath a clear blue sky.
On this page
  1. Coriolis mass flow meter selection starts with the measured variable
  2. Start with the fluid and its operating state
  3. Check flow range, pressure drop and line conditions
  4. Decide which measured outputs the process needs
  5. Allow for installation and fluid disturbances
  6. Prepare a pre-purchase Coriolis meter checklist
  7. Frequently asked questions

Key takeaways

  • Check the fluid phase and identify bubbles, slugs, solids or changing composition before selecting a meter.
  • Compare minimum, normal and maximum flow with the meter’s published operating range.
  • Confirm pressure drop at expected operating conditions against the process pressure budget.
  • Specify which outputs are needed and what each value will be used for.
  • Review orientation, piping, calibration information and process-specific accuracy before purchase.

Coriolis mass flow meter selection starts with the process, not the nominal pipe size. Confirm the fluid phase and operating conditions, then check the expected flow range, acceptable pressure drop and measurements needed for control or reporting.

A Coriolis meter measures mass flow directly and may also provide density, volume flow, fraction flow and temperature. The BCMF Coriolis mass flow meter lists these outputs, but their suitability depends on the actual fluid and operating conditions. Use the checks below to build a shortlist before requesting a quotation.

Coriolis mass flow meter selection starts with the measured variable

A Coriolis meter uses vibrating measuring tubes. As fluid passes through them, the flow causes the tubes to twist or distort. Detectors register this movement, which is proportional to mass flow. The BCMF product page describes two parallel tubes driven close to their resonance frequency, with detected distortion used to measure mass flow directly.

Density is another possible output. It can be determined from the behaviour of the vibrating tubes, while volume flow can be calculated from mass flow and density. The BCMF product page also lists fraction flow and temperature. These are distinct outputs, so identify which values the process needs and how each will be used. An output available from an instrument is not automatically suitable for every fluid or process purpose.

Start with the measurement objective. Is the control system intended to regulate the mass added to a batch, monitor a material balance or display volume flow? Is density needed for a process decision, or would it provide useful context for operators? Record the required value, its purpose and the performance the process needs. This makes it easier to assess the meter against the job rather than selecting it solely from a feature list.

Consider the complete measurement path as well as the sensor. The measured value must reach the control or monitoring system that needs it and be understandable to the people using it. The flow measurement and monitoring systems page provides broader context for how flow instruments fit into a system. Include the intended signal or data destination in the enquiry so the proposed meter can be considered as part of the process, not in isolation.

A large curved silver pipeline with segmented insulation runs through a bright facility on metal supports.

Start with the fluid and its operating state

Record whether the service is normally a liquid or a gas. Then describe what happens during start-up, shutdown, cleaning, batching and abnormal operation. A fluid that is single-phase during steady running may contain bubbles or gas pockets during a transition. A gas stream may also change in pressure or composition. These operating details affect the application review and how readings should be interpreted.

For liquid service, identify the likelihood of entrained gas, bubbles, flashing or slugs. Do not assume that performance in normal single-phase service applies unchanged when gas is mixed into the liquid. Research on entrained gas in Coriolis measurement reports that different bubble conditions can disturb measurements through different mechanisms. Describe how often gas is present, how it enters the line and whether it passes through as dispersed bubbles or larger slugs. Include intermittent events, even if the liquid is usually free of gas.

For gas service, provide the operating pressure and gas conditions for application review. An EPA technical reference on Coriolis meters notes that low-pressure gases can be difficult to measure because their density may be too low for accurate operation. A general statement that a meter is suitable for gases does not establish suitability for every gas density or pressure. Ask for the intended conditions to be checked against the selected meter’s published limits. This is a key part of Coriolis meter gas measurement, particularly where pressure or composition varies.

Describe solids and changes in composition as well. Depending on the service, erosion, coating or clogging may affect performance or maintainability. Flashing and cavitation are further considerations where process conditions could produce them. Include normal and changing fluid states in the enquiry rather than sending only the fluid name. If a disturbance occurs intermittently, note when it happens and how long it lasts. That gives the reviewer a clearer picture of the actual service than a single steady-state description.

Check flow range, pressure drop and line conditions

Gather the expected minimum, normal and maximum flow rates. Compare all three with the selected meter’s stated operating range. Sizing only around the normal rate can miss important operating cases, such as reduced production, peak demand or flushing. If an expected rate falls outside the published range, request an application review rather than assuming the meter will provide suitable performance.

Check Coriolis meter pressure drop at the actual operating conditions. Flow through a meter creates a pressure loss, and the process must be able to accept it. The EPA reference identifies specific minimum and maximum operating flow rates and says pressure drop must remain within what the system can tolerate. Compare pressure-drop information for the proposed meter size and duty with the pressure budget for the whole line. Consider the effect on downstream equipment and process control if the added loss is too high.

Pressure drop is not an isolated instrument detail. It can affect whether the system maintains the required flow and whether an existing pump or pressure-control arrangement remains suitable. Ask for pressure-drop information at the expected operating conditions, not a general value detached from the application. If the process has limited pressure margin, include that constraint in the sizing discussion. Where the duty varies, ask how the pressure drop is expected to relate to the operating points under consideration.

Also describe how the process flow behaves. A steady duty and an intermittent duty are different selection cases. If flow changes sharply, occurs in short dosing events or stops between batches, provide that pattern and the time scale of the changes. The reviewer needs to understand both the range and the way the process moves through it. This helps assess whether the proposed meter’s published operating range fits the actual duty, rather than just one nominal value.

Do not treat the meter’s nominal size as proof that the process will operate within its range or pressure-drop limit. Provide the process rates and pressure constraints, then compare them with the data for the specific meter being considered. If the required information is not available, make it an explicit question in the enquiry rather than relying on an assumption.

Parallel water-treatment channels and pipework viewed from above in soft morning light.

Decide which measured outputs the process needs

Separate the requirement for direct mass flow from requests for other values. Mass flow may be the key quantity for dosing, batching or material accounting. Density, volume flow, fraction flow and temperature may also be useful, but state the reason for each. This makes it possible to check that the output is available in the intended configuration and appropriate for the fluid and operating conditions.

If the process needs volume flow, confirm how it will be obtained and whether density measurement is suitable for the fluid. Volume flow calculated from mass flow and density depends on both values. If a fraction measurement is required, describe what fraction is relevant and how the result will be used. Do not assume that a displayed secondary value automatically satisfies a process or reporting requirement.

The BCMF product page lists mass flow, density, volumetric flow, fraction flow and temperature. It states ±0.2% accuracy for liquid mass-flow measurement. Treat that as a product-page specification, not a guarantee for every process condition. Ask whether the stated accuracy applies to the intended fluid, flow range, installation and operating state. Clarify the required performance for each output rather than assuming one accuracy statement covers them all.

If the process only needs volumetric flow, compare the measurement principle with other suitable options instead of treating Coriolis as the default. The explanation of how electromagnetic flow measurement differs can help frame that comparison. The shortlist should reflect the fluid and measurement requirement, not simply the number of outputs an instrument offers.

Allow for installation and fluid disturbances

Check the proposed orientation and piping arrangement against the meter documentation and actual process conditions. The BCMF product page gives model-specific orientation guidance: the sensor faces downward for liquids, upward for gases and sideways for turbid liquids. Confirm the current documentation for the particular application before finalising the layout. Do not transfer an orientation recommendation from one service to another without checking the fluid state and installation details.

Review the upstream piping and identify disturbances that could affect the flow presented to the meter. Research on Coriolis meter installation effects has examined specific meter configurations and upstream disturbances. Those findings relate to the configurations tested, not a universal correction factor or allowance for every installation. Share the proposed arrangement with the application reviewer and follow the installation documentation for the selected model.

For liquid lines, discuss whether gas can collect near the sensor or pass through as bubbles or slugs. For gas lines, check the operating density and pressure against the published limits for the meter under consideration. Consider whether the line can maintain the required operating state during measurement. A meter assessed for one steady condition should not be assumed suitable when the process frequently changes phase or composition.

Installation review is part of selection, but it does not replace application review. A suitable pipe layout cannot compensate for an unsuitable flow range or fluid condition. Equally, do not reject a meter solely because an installation study found an effect in a different configuration. Assess the proposed arrangement, the model documentation and the process duty together. Record unresolved piping or orientation questions before purchase so they can be answered against the selected model’s documentation.

Prepare a pre-purchase Coriolis meter checklist

Prepare a concise application record before requesting a recommendation. Include the fluid name and whether it is normally a liquid or gas. Describe any expected bubbles, slugs, solids, flashing, coating, clogging or changing composition. Note the operating pressure and temperature, along with the expected minimum, normal and maximum flow rates. State the pressure drop the process can accept, or explain what information is needed to determine that limit.

List each required output and its purpose. Identify whether mass flow is the primary value and whether density, volume flow, fraction flow or temperature is also needed. Describe how each value will be used, such as for dosing, process control or monitoring. If measurement performance matters for product quality or process accounting, state the required accuracy and ask how the published specification applies to the intended conditions.

Ask for application confirmation against the selected meter’s published specifications. Request operating-range and pressure-drop information for the proposed sizing, and ask whether each required output is suitable for the fluid. The BCMF page states that the meter is factory calibrated before shipment. Ask what calibration information is supplied and how it relates to the intended operating range. Calibration evidence can include comparison with a reference flow standard and a calibration factor reported against mass flow. Ask what conditions were covered and whether the calibration information addresses the process duty. Factory calibration is useful information for a shortlist, but the enquiry should clarify what evidence is provided and whether it meets the process requirement. NIST’s liquid-flow calibration publication describes this type of comparison and reporting.

Finally, check that the instrument fits the wider system. Consider the installation location, signal requirements and how operators will use the measurement. The pages on process industries using instrumentation and monitoring and flow measurement and monitoring systems provide broader context for system-level decisions. Keep the shortlist tied to documented requirements: fluid state, flow range, pressure drop, outputs, installation and calibration information.

A useful enquiry should let the reviewer compare the application with the meter’s specifications without guessing at the process conditions. If some operating details are not yet known, identify them as open questions. That is more useful than presenting uncertain values as fixed design requirements.

Frequently asked questions

Can a Coriolis meter measure both mass flow and density?

Yes. The BCMF product page lists both mass flow and density, along with volume flow, fraction flow and temperature. Confirm which outputs are available and suitable for the intended fluid and operating conditions. If the process depends on a secondary output, specify its purpose and the performance required rather than relying only on its presence in the product description.

Is a Coriolis meter suitable when gas bubbles may be present in a liquid?

Entrained gas and bubbles can disturb Coriolis measurement, and different bubble conditions can affect performance differently. Describe how often gas is present and whether it occurs as dispersed bubbles or slugs. Include when it happens in the operating cycle and request an application review before selecting the meter for that service.

Does a Coriolis meter need a straight run of pipe upstream?

Do not assume a universal straight-run requirement or a universal allowance for upstream disturbances. Check the selected model’s installation documentation and review the proposed piping arrangement for the actual application. Research on installation effects concerns specified configurations, so it should not be treated as a substitute for model-specific guidance.

What information should I send for a sizing review?

Provide the fluid and phase, operating pressure and temperature, minimum, normal and maximum flow, acceptable pressure drop, required outputs, likely disturbances and proposed installation arrangement. Include the intended measurement performance and ask for calibration information relevant to the operating range. If gas, solids or changing composition may occur, describe those conditions and when they arise.

To discuss an application, contact our engineers with the process details, the meter data being reviewed and any questions that still need confirmation.

LKS Engineering TeamEngineers at LKS Group, supplying and servicing instrumentation, valves and monitoring systems in Malaysia since 1998.

From the catalogue

Flow Systems

Get in touch

Need a quote or technical advice?

Tell us about your application and our engineers will recommend the right instrument or system.

  1. 01Share your applicationProcess, medium, range and site conditions.
  2. 02Engineer recommendationWe match the right instrument or system to your process.
  3. 03Quotation and supportSupply, installation, calibration and after-sales service.